| Name | Last modified | Size | Description | |
|---|---|---|---|---|
| Parent Directory | - | |||
| PDE_lin.mat | 2010-07-15 11:08 | 50K | ||
| README.html | 2010-07-15 11:08 | 277 | ||
| readme.txt | 2010-07-15 11:08 | 268 | ||
See paper "Contrallability analysis of two-phase pipleline-riser systems at slugging conditions" The linearized model has 1 input, 1 output and 50 states. It is for the operating point with valve opening Z=30%. Unstable poles at 0.0045 +- 0.0108i