Abstract.
A conventional batch distillation column operated under feedback
control applying the proposed policy is compared to the multivessel
batch distillation column. In some cases we found that an increase in
production rate up to 50% is possible by using multivessel batch
distillation instead of a conventional batch distillation column with
similar column length. Besides the considerable reduction in energy
usage, the main advantage with the multivessel batch distillation
column is probably its much simpler operation compared to a
conventional batch distillation column.