Repetitive-Control System for Harmonic Elimination in Three-Phase Voltage-Source Inverters
| Authors: | Roncero Pedro, E.T.S. Ingenieros Industriales, University of Castilla-La Mancha, Spain Feliu-Batlle Vicente, E.T.S. Ingenieros Industriales, University of Castilla-La Mancha, Spain García-Cerrada Aurelio, E.T.S. de Ingeniería (ICAI), Universidad Pontificia Comillas, Spain García-González Pablo, E.T.S. de Ingeniería (ICAI), Universidad Pontificia Comillas, Spain |
|---|
| Topic: | 6.3 Power Plants and Power Systems |
|---|
| Session: | Control of Power Converters |
|---|
| Keywords: | Active Filters, Harmonic Control, Voltage Inverter Switches |
|---|
Abstract
This paper presents an algorithm based on a repetitive-control scheme to eliminate the low-frequency-harmonic contents of the output voltage in voltage-source inverters. The proposed controller can be used to minimise unexpected output-voltage harmonics due to practical implementation aspects of the pulse-width-modulation algorithm (switch dead time, for example).The controller can be implemented using the Park's transformation with a rotating reference frame for balanced three-phase voltage-source inverters. Simulation results are presented to illustrate the main contribution of this work.