15th Triennial World Congress of the International Federation of Automatic Control
  Barcelona, 21–26 July 2002 
LIMITATIONS IN THE CONTROL OF A DC-DC BOOST CONVERTER
Cunha, F. B.* and Pagano, D. J.*
* Departamento de Automação e Sistemas,
Universidade Federal de Santa Catarina,
88040-900, Florianópolis, SC, Brasil
e-mail:{daniel, felipe}@das.ufsc.br

This paper analyses the control of a DC-DC boost converter using both instantaneous and averaged models. The control objectives are discussed and the main focus is the load disturbance rejection. The transient performance is shown to be limited by saturation constraints on the control variable. In particular, it is shown that the transient behaviour of the output voltage in the presence of load disturbances cannot be minimized beyond a certain limit by the control strategy. Simulation results obtained using two different control laws put in evidence these limitations.
Keywords: nonlinear systems, switching systems, DC-DC boost converters, constraints, saturation, adaptive sliding mode control
Session slot T-We-M03: Applications of Adaptive Control/Area code 3b : Adaptive Control and Tuning