# ChemSep Messages 1==Cannot reload file 2==File was not saved before 3==Cannot load more than maximum of 4== components 5==Load [x] to maximum of 6==Total reflux column must consist of minimal 2 stages 7==Maximum number of feeds allocated 8==Could not autosetup axis 9==Select graph first 10==Can only clip graph data when a common basis is used 11==Cannot assign both key components to the same component 12==Cannot delete one of the standard units sets 13==Units definitions file does not exist: 14==You must save the sep file in order to solve it 15==Simulation executable is missing, check the paths: 16==Input incomplete 17==Remove heater/cooler 18==adapt stage to valid range 19==There is already a heater/cooler for this stage, choose a different stage 20==There is already an efficiency for this stage, choose a different stage 21==Error loading the defintions file|Nonequilibrium model not available 22==Remove feed 23==Maximum number of sidestreams allocated 24==Remove sidestream 25==Maximum number of pumparounds allocated 26==Remove pumparound 27==Maximum number of sections allocated 28==Remove section 29==Do you really want to change the internals type of this section (internals parameters information will be lost) 30==Do you really want to change the model of this internal (model parameters information will be lost) 31==No input of thermodynamic model parameters required 32==Remove reaction 33==Maximum number of reactions allocated 34==Maximum number of reactive zones allocated 35==Remove reactive zone 36==Are you sure you want to reset all the interaction parameters 37==Do you really want to reset the parameters of the section 38==There is already a section for this stage, choose a different stage 39==Do you want to load the generated file in your default browser 40==Exporting 41==Illegal characters have been removed from the filename (~`!@#$%^&*(){}[]|";<> ,'?) 42==Substitute component [c] with 43==New with stream 44==Remove component 45==Component [c] already present # Feeds menu 46==Feed: 47==Name 48==Stage 49==State 50==Pressure 51==Vapour fraction 52==Light fraction 53==Temperature 54==Flowrates 55==Total flowrate 56==ChemSep selected new paths. Do you want to save the new path configuration 57==Hintsfile does not exist. Enter a valid filename 58==Synonyms file does not exist. Enter a valid filename 59==Cannot reload file [n] as it does not exist (it was most probably deleted) 60==Input is OK 61==IO Error [ior] occured. Flag is now resetted # 62==Maximum number of stages in this version is 63==No matching parameters found 64==An error occured during loading of 65==Converted: 66==Cannot set the total flow when one of the component flows is not set 67==Default efficiency must be > 0 68==Stage efficiency must be > 0 69==Cannot adjust section height when integration (stage) height is unknown 70==Cannot increase stages to accomodate height 71==Adapt section and number of stages to obtain 72==Computed design contains different type of internals.|Cannot import the designed internals 73==Use computed internals design 74==Reached maximum number of plots ( 75==No results present: Can't use old results.|Switched initialization to automatic 76==Save first 77==Keep partially loaded data 78==Do you want to adapt the property data 79==Do you want to estimate missing (*) parameters? 80==Do you want to load the generated file in your browser 81==Delete data set 82==Delete graph 83==Delete units set 84==Continue checks 85==Overwrite file 86==Running simulator # Checks: 87==No 88== selected 89== specified 90== not specified 91== is zero 92==Component 93==For an extractor 94== an enthalpy model other than None is required 95== NO enthalpy model must be used 96== specification not selected 97==Column needs a feed to stage [s] and it should be a [p] 98==Column needs a feed to stage [s] and its feed flow cannot be zero 99==Products flow > total feeds flow 100==Property data missing for 101==Illegal specification 102==For duty specification 103==Subcooled flows: 104==Superheated flows: 105==Design parameter 106==must be zero 107==should be positive 108==should be negative 109==Column needs a feed to stage [s] 110==Number of stages not specified 111==No feeds specified 112==No components selected 113==Heat duty specified: 114==For heater/coolers 115==For a T&P feed specification 116==You must save the file before it can be solved 117==The integration height and bed height must be entered (or select a different internal) 118==The selected continuous internal does not have an integration height, accept default of 0.1m # 119==File [file] already exist, overwrite 120==Save table as spreadsheet file 121==New section 122==Enter first stage of section 123==Cannot add a new section starting at the specified stage; another section already starts at this stage 124==Do you want to adapt the sections automatically 125==Do you want to save the current input 126==Problem specification is incomplete, are you sure you want to close this window # setting names to streams 127==Feed 128==Sidestream 129==Pumparound # 130==Warning: Run instructions larger than 250 characters can cause problems under MS Windows # 131==Do you really want to reset the model parameters of # 132==Do you want to delete RC line [n] 133==Select distinct components 134==z1 not in range 135==z2 not in range 136==z3 not in range (z1+z2>1) 137==Enter pressure 138==Initialize residue cruve map first # 139==Error: Cannot execute tool 140==Tool must be identified with a name 141==Select a macro to insert in the arguments # FUG: 142==Interaction parameters are too large. Switch to chemical theory 143==Error ------------------------------------------------------- Select other components? 144==Not calculated # K&H: 145==Switched to use the same EOS for K-model and enthalpy 146==Use consistent EOS to compute enthalpy 147==No conversion of the interaction parameters was done! Please reload the parameters from the library to convert them! 148==You cannot vary the same variable twice! Please replace on of the variable definitions in the parametric study 149==Specify correct start and end values for the input variables 150==Specify correct number of steps (steps>0 and steps<100) 151==You need at least one input and one result variable 152==Select first the result variable to delete 153==Are you sure you want to delete 154== as result variable 155==Parametric Study 156==Enter the result variable to display 157== as input variable 158==Enter the input variable to vary 159==First select the result variable to delete 160==Do you want to remove all result variables 161==Reload the sep-file to compute the physical properties 162==The Wilson K-value model does not use the Wilson activity coefficient model but is a variation of Raoult's law that was devised by G.M. Wilson. To use the Wilson activity coefficient model please select the DECHEMA or Gamma-Phi K-value model. # 163==Invalid range for stage number: 1-[s] 164==Invalid temperature range 165==Invalid flow rate 166==Delete user initialisation stage [s] 167==Ommit initialization for unspecified stage 168==The COSE failed to pass the component selection on to ChemSep. Therefore, you need to select them yourself. Be careful to select the same components and to select them in the same order 169==Compounds [s] not found in ChemSep libraries. ChemSep relies on COSE to fully supply all pure compound data 170==This version of ChemSep is limited to [s] compounds for the column simulator. Please visit http://www.chemsep.org/program/distribution.html for larger versions 171==No units definition file found; cannot do unit conversions 172==No component library file found; you cannot select components until you selected a PCD file 173==No messages file found; cannot display many messages correctly 174==No limits file found; mismatch between maximum #components/#stages can occur 175==Under development 176==This is not a sep-file 177==This version doesn''t include reactive distillation 178==Help us translate ChemSep. Make a copy of the "chemsep.msg" and the "chemsep.hnt" files, translate them into your language, and mail them to us at kooijman@chemsep.org 179==Graph not defined: check axis settings and import file 180==requires nonequilibrium column! # RCMAP 181==Top product Concentration Trajectory 182==Enter reflux ratio 183==Bottom product Concentration Trajectory 184==Enter stripping ratio 185==Error loading results csres 186==No data file specified under "import data" to compare with 187==Data file specified under "import data" does not exist 188==No set is selected to compare data with, please select one 189==The set is undefined: please check X & Y variables and number of points > 1 190==Calculate deviations in import file with set [i] 191==Add deviations as line segments in plot data 192==Use comments field to store plot file 193== diagram 194==Do you want to load the generated file in Excel 195==Do you want to view the generated file 196==Rename sidestream into water-draw 197==Water-draw